SATEL's Laboratory has a wide set of different testing equipment:
Schaffner GTEM LT-950
GTEM Cell for emission and immunity testing
(testing of devices in isolation from external electromagnetic fields)
(testing of devices in isolation from external electromagnetic fields)
Schaffner GTEM LT-950
• frequency range: 9 kHz - 6 GHz
• equipment emission and resistance to electromagnetic fields testing
• equipment emission and resistance to electromagnetic fields testing
Rhode & Schwarz FSVR30
Real-Time Spectrum Analyzer
Rhode & Schwarz FSVR30
• real-time smooth spectrum measurement and display (in the time domain with a span of up to 40 MHz)
• registration of all events for analysis, regardless of their duration
• frequency range: 10 Hz - 30 GHz
• real-time spectrum analysis up to 30 GHz
• measurement of equipment radiated and conducted emission
• intuitive touch screen operation
• registration of all events for analysis, regardless of their duration
• frequency range: 10 Hz - 30 GHz
• real-time spectrum analysis up to 30 GHz
• measurement of equipment radiated and conducted emission
• intuitive touch screen operation
Rhode & Schwarz ZVL3
Vector Network Analyzer
(VNA - a form of radio network analyser)
(VNA - a form of radio network analyser)
Rhode & Schwarz ZVL3
• measurement of amplitude and phase properties
• measurement of S parameters
• frequency range: 9 kHz - 3 GHz
• ports: 2 x 50 Ohm
Wide applications in the design of wireless devices.
• measurement of S parameters
• frequency range: 9 kHz - 3 GHz
• ports: 2 x 50 Ohm
Wide applications in the design of wireless devices.
Emtest dito ESD tester
advanced tester for ESD pulse simulation
Tester ESD emtest "dito"
• advanced ESD tester to simulate ESD pulses (according to IEC 61000-4-2 and other standards)
• voltage range: 500 V - 16,500 V
• voltage range: 500 V - 16,500 V
Compact NX5
Multifunctional test generator for transients (EFT/Burst, Surge & Power Fail) up to 5.5 kV
Compact NX5
Ultra compact and most versatile tester - addressing transient and power fail requirements - compliant with international standards (basic publications and general standards) and product standards.
• Burst module (IEC/EN 61000-4-4) up to 5.5 kV
• Surge module (IEC/EN 61000-4-5) up to 5 kV
and coupling networks:
• CNV 508T5 coupling network for unshielded asymmetrical lines (communication lines)
• CNV 504N coupling network for unshielded symmetrical lines (signal/data lines)
• Burst module (IEC/EN 61000-4-4) up to 5.5 kV
• Surge module (IEC/EN 61000-4-5) up to 5 kV
and coupling networks:
• CNV 508T5 coupling network for unshielded asymmetrical lines (communication lines)
• CNV 504N coupling network for unshielded symmetrical lines (signal/data lines)
IMMUNITY TEST SET
Signal and spectrum analysis and real-time spectrum analysis equipment
IMMUNITY TEST SET
• Rhode & Schwarz NRVD power meter
• Rhode & Schwarz generator 9 kHz - 6 GHz
• Schaffner amplifier 80 MHz - 1 GHz
• Schaffner amplifier 0,8 GHz - 3 GHz
• Rhode & Schwarz amplifier 2,5 GHz - 6 GHz
Set for generating electromagnetic field in a GTEM cell and testing the influence exerted on the operation of tested devices (IEC/EN 61000-4-3) - in conjunction with special Rhode & Schwarz software.
• Rhode & Schwarz generator 9 kHz - 6 GHz
• Schaffner amplifier 80 MHz - 1 GHz
• Schaffner amplifier 0,8 GHz - 3 GHz
• Rhode & Schwarz amplifier 2,5 GHz - 6 GHz
Set for generating electromagnetic field in a GTEM cell and testing the influence exerted on the operation of tested devices (IEC/EN 61000-4-3) - in conjunction with special Rhode & Schwarz software.
Schaffner GTEM LT-950
GTEM Cell for emission and immunity testing
(testing of devices in isolation from external electromagnetic fields)
(testing of devices in isolation from external electromagnetic fields)
- frequency range: 9 kHz - 6 GHz
- equipment emission and resistance to electromagnetic fields testing
Rhode & Schwarz FSVR30
Real-Time Spectrum Analyzer
- real-time smooth spectrum measurement and display (in the time domain with a span of up to 40 MHz)
- registration of all events for analysis, regardless of their duration
- frequency range: 10 Hz - 30 GHz
- real-time spectrum analysis up to 30 GHz
- measurement of equipment radiated and conducted emission
- intuitive touch screen operation
Rhode & Schwarz ZVL3
Vector Network Analyzer
(VNA – a form of radio network analyser)
(VNA – a form of radio network analyser)
- measurement of amplitude and phase properties
- measurement of S parameters
- frequency range: 9 kHz - 3 GHz
- ports: 2 x 50 Ohm
Wide applications in the design of wireless devices.
Emtest dito ESD tester
advanced tester for ESD pulse simulation
- advanced ESD tester to simulate ESD pulses (according to IEC 61000-4-2 and other standards)
- voltage range: 500 V - 16,500 V
Compact NX5
Multifunctional test generator for transients (EFT/Burst, Surge & Power Fail) up to 5.5 kV
Ultra compact and most versatile tester – addressing transient and power fail requirements – compliant with international standards (basic publications and general standards) and product standards.
- Burst module (IEC/EN 61000-4-4) up to 5.5 kV
- Surge module (IEC/EN 61000-4-5) up to 5 kV
and coupling networks:
- CNV 508T5
coupling network for unshielded asymmetrical lines (communication lines) - CNV 504N
coupling network for unshielded symmetrical lines (signal/data lines)
IMMUNITY TEST SET
Signal and spectrum analysis and real-time spectrum analysis equipment
- Rhode & Schwarz NRVD power meter
- Rhode & Schwarz generator 9 kHz - 6 GHz
- Schaffner amplifier 80 MHz - 1 GHz
- Schaffner amplifier 0,8 GHz - 3 GHz
- Rhode & Schwarz amplifier 2,5 GHz - 6 GHz
Set for generating electromagnetic field in a GTEM cell and testing the influence exerted on the operation of tested devices (IEC/EN 61000-4-3) – in conjunction with special Rhode & Schwarz software.
SATEL’s Laboratory uses equipment and software from the world leading manufacturers. Tests are conducted by qualified scientists.